• English
    • Türkçe (Turkish)
  • NEWSLETTER
  • CONTACT US
  • FAQs
CSO TRADING CSO TRADING
Select category
  • Select category
  • EMAS
    • Basic Switches
    • Buttons
    • Cam Switches
    • Contactors
    • Control Boxes And Pedals
    • Electronic Products Group
    • Level Control Float Switches
    • Light Towers
    • Limit Switches
    • Motor Protection Switches
    • Signals
  • EMKO
    • Control Devices For Industrial Applications
      • Air Conditioning Controller
      • Cooking – Furnace
      • Differantial Controller
      • Dijital Power Regulator
      • Incubator Hatcher Controller
      • PLC Built-In Operator Panel
      • Profile Step Control Device
    • Generator Set Controller
      • ATS
      • Auto Start Moto-Pump Protection Control
      • Automatic Genset Controllers
      • Automatic Mains Failure Unit
      • AVR
      • Battery Charger
      • Manual
      • Modules
    • Measurement Control Devices
      • Counters
      • Digital Potentiometer
      • Digital Tachometer
      • Heating Cooling
      • Process Control Devices
      • Process Indicators
      • Timers
    • Poultry Automation
      • EPC Series
      • EPC-N
      • Hatcher Controller
    • Sensors
      • Humidity
      • Thermocouples
      • Thermoresistances
  • ENKO
    • Automatic Mains Failure Units – AMF Series
    • Automatic Transfer Switch Units – ATS Series
    • Battery Charger Units – EBC Series
    • Engine Start Units – ESR Series
    • Manual Start Units – MSU Series
  • ENTES
    • Electrical Measurement
    • Power Factor Correction
    • Power Quality and Energy
    • Protection & Control
  • KLEMSAN
    • Automation Products
    • Terminal Blocks and Accessories
  • METE ENERJİ
    • High Amperage
    • MeteCEE
    • MeteCON
    • MeteSOLID
    • MeteVENT
  • OMRON
    • HMI
    • Industrial PC
    • Input and Output (I/O)
    • Monitoring Products
    • PLC
    • Temperature Controllers
  • YASKAWA
    • AC Drives
Email: [email protected]
Menu
CSO TRADING CSO TRADING
Browse Categories
  • OMRON
    • Input and Output (I/O)
    • Monitoring Products
    • PLC
    • Temperature Controllers
  • SCHNEIDER
  • EMKO
    • Measurement Control Devices
      • Heating Cooling
      • Process Control Devices
      • Process Indicators
      • Counters
      • Timers
      • Digital Potentiometer
      • Digital Tachometer
    • Sensors
      • Thermocouples
      • Thermoresistances
      • Humidity
    • Generator Set Controller
      • Automatic Genset Controllers
      • Automatic Mains Failure Unit
      • ATS
      • Manual
      • Modules
      • Battery Charger
      • AVR
      • Auto Start Moto-Pump Protection Control
      • Old Products
    • Control Devices For Industrial Applications
      • Profile Step Control Device
      • Cooking – Furnace
      • Differantial Controller
      • Air Conditioning Controller
      • PLC Built-In Operator Panel
      • Digital Temperature Humidity Controller
      • Incubator Hatcher Controller
      • Dijital Power Regulator
    • Poultry Automation
      • Hatcher Controller
      • EPC Series
      • EPC-N
  • ENTES
    • Power Quality and Energy
    • Electrical Measurement
    • Power Factor Correction
    • Protection & Control
  • YASKAWA
  • KLEMSAN
    • Terminal Blocks and Accessories
    • Automation Products
  • EMAS
    • Cam Switches
    • Control Boxes And Pedals
    • Buttons
    • Signals
    • Limit Switches
    • Basic Switches
    • Contactors
    • Motor Protection Switches
    • Level Control Float Switches
    • Electronic Products Group
    • Light Towers
  • METE ENERJİ
    • MeteCON
    • MeteCEE
    • MeteVENT
    • MeteSOLID
    • High Amperage
  • PAKKENS
  • Home
  • About Us
  • Blog
  • Brands
  • Contact Us
Click to enlarge
Home ENKO Battery Charger Units – EBC Series ENKO EBC 1205
ENKO MSU 5.2
Back to products
ENKO EBC 1210

ENKO EBC 1205

Charging Lead-Acid batteries in three controlled stages for best performance

SMPS technology for maximum efficiency and reliablity with minimum heat dissipation.

Categories: Battery Charger Units – EBC Series, ENKO
Share:
  • Description
  • Shipping & Delivery
Description

EBC 1205M can deliver continuous charging current of 5A into 12V battery system (voltage is set to 13.8Vdc, with an option of up to 14.7Vdc) These battery chargers are designed with performance in mind and special care is taken for protecting and extending the life-time of the battery.

EBC 1205M is designed with “Switched Mode” technology, where the switching transistor has only two states, ON or OFF, which increases the overall efficiency, hence reduces the excess heat dissipation and in return, increasing the device life-time and reliability.

The control system is also designed in such a way that; battery is charged in three stages:

  • Constant current mode (protecting battery cells)
  • Constant voltage mode (reducing the charge current)
  • Float charge (compensation of internal self-discharge)

Constant current mode makes sure that; when the battery is drained down below its rated capacity, the high charge current flow into the battery is limited in order to protect the cells and reduce damage to the plates.

As the battery capacity is recovered, each cell voltage reaches up to 2.30Vdc to 2.45Vdc level, which means that the required charging current starts to reduce.

When the required battery terminal voltage is fully reached, the charger keeps supplying just enough current in order to compensate for the internal self-discharge (float charge). This ensures that the battery can maintain its high charge state and deliver its rated out-put current, when ever required.

Typical Cell charging characteristics of the charger is shown in the table. The Cell is part of the battery and 12V batteries contain 6 cells.

Factory setting of the charger allows each Cell to be charged to 2.30Vdc, which corresponds to 13.80Vdc terminal voltage. User can use an option up to 2.45Vdc per Cell, which corresponds to 14.70Vdc battery terminal voltage.

Each charging stage can be seen on the table. Initial cell charging is achieved with constant current mode, which limits the current such that it does not damage the cell plates. Normal charging time should be calculated as 10hr to 12hr. This requires typical charging current rating of 10% of the rated battery current capacity.

After the initial charging stage is completed, charge current starts to decrease as the cell voltage approaches 2.30Vdc. This takes approximately 60% of the charging period and is necessary to equalize each Cell voltage within the battery. During this period, the charger ensures stable constant voltage across the battery terminals.

After the charging is completed, the battery keeps draining current from the charger in order to compensate its internal resistive losses, called Self Discharging of the battery. This needs to be compensated in order to keep the battery charge at its highest condition.

If reverse polarity protection is required, user has to fit an external fuse in the charge circuit with the indicated rating in the table.

Charge failure output can be used with a relay, connected to V+ so that other devices can be controlled through the alarm relay. Under normal operating conditions, the relay will be energized.

The alarm output is solid state relay, which can sink up to 50mA DC current.

The charger enclosure is made from Aluminum alloy metal sheet and can either be screw fitted directly on the panel or it can be used together with rail mounting kit. Rail mounting kit is an option and has to be decided during purchase. Total weight is 330gr.

Care should be taken in order to make sure that the perforations on the metal enclosure is not covered and
free air ventilation is maintained within the panel. Otherwise, excess accumulated heat will degrade the overall efficiency of the charger unit.

Earth connection has to be made securely as the case is made from metal. Also proper noise filtering can only be active with a good earth connection of the charger unit.

KEY FEATURES

    • Wide input voltage Range 150Vac to 300Vac
    • 45Hz to 450Hz input supply frequency range
    • Capability to work direct from 250Vdc to 400Vdc supply voltage
    • 13.8Vdc factory set DC output terminal voltage (option up to 14.7Vdc)
    • 5Adc continuous output current into Load
    • Capability to work continously into short-circuit
    • Parallel connection for higher output current rating and redundant operation
    • Series connection capability for higher output voltage requirements
    • No cooling fans, all natural convection cooling
    • Aluminum alloy case for robust handling and easy mounting
    • Both screw type or rail mount kit avaliable (Rail mount kit is an extra)
    • Overall efficiency > 82%
    • Boost charge function
    • Reverse power and reverse polarity protection with internal fuse,
    • Noise input filter
    • Solid State contact alarm output
    • Compatible with all types of Lead Acid and Nikel Cadmium (Ni-Cad application must be stated upon order) batteries
    • 3 stage battery charging

    Constant Current Mode – to protect the battery cells

    Constant Voltage Mode – to reduce the charge current

    Float Charge Mode – to compensate internal self-discharge

KEY BENEFITS

  • SMPS technology increases the overall efficiency, hence reduces the excess heat dissipation in return, increasing the device life-time and reliability
  • Elimination of fans and moving parts maximize the reliability
  • The power de-rating function ensures the charger protects itself at high temperatures and does not fail
  • Low output voltage ripple allows the unit to be used as a Power Supply if required (Must be stated while ordering)
  • Three stage charging ensures best performance and reliability
  • The noise input filter provides EMC reduction
  • User operated Boost Charge function to replenish the battery charge storage capacity to high levels
  • The alarm output can be connected to a Gen-set controller for monitoring
Shipping & Delivery

Shipments and returns

Your pack shipment

Packages are generally dispatched within 1 week after receipt of payment and are shipped via DHL or EMS post service ( based on agreement) with tracking number. If you prefer delivery by your account number of forwarder please contact us before choosing this method. Whichever shipment choice you make, we will provide you with a link to track your package online.

Shipping fees include handling and packing fees as well as postage costs. Handling fees are fixed, whereas transport fees vary according to total weight of the shipment. We advise you to group your items in one order. We cannot group two distinct orders placed separately, and shipping fees will apply to each of them. Your package will be dispatched at your own risk, but special care is taken to protect fragile objects.

Boxes are amply sized and your items are well-protected.

Related products

ENKO EBC 2410

Charging Lead-Acid batteries in three controlled stages for best performance

SMPS technology for maximum efficiency and reliablity with minimum heat dissipation.

Read more

ENKO MSU 5.2

High performance with friendly user interface. Powerful program menu for enhanced control applications.

MSU 5.2 is equipped with Graphical LCD display and provides embedded inteligence for Gen-Set control applications, where high integration flexibility and "on-site" system monitoring is required.

Read more

ENKO MSU 3.1

Efficient and versatile control for all Gen-Set applications

MSU 3.1 offers versatile control functions for single or multiple Generator control applications with flexible load control.

Read more

ENKO EBC 2405

Charging Lead-Acid batteries in three controlled stages for best performance

SMPS technology for maximum efficiency and reliablity with minimum heat dissipation.

Read more

ENKO MSU 2.0

Efficient and simple control for single Gen-Set applications

MSU 2.0 offers all necessary control functions for single Generator applications.

Read more

ENKO AMF 3.4

Efficient and versatile control for all Gen-Set applications.

AMF 3.1 offers versatile control functions for single or multiple Generator/Mains applications.

Read more

ENKO AMF 4.0

Friendly user interface with analog bar graph displays...

AMF4.0 controller includes two analog bar-graph displays to indicate direct readings from engine temperature and oil pressure gauges. AMF4.0 offers flexible control of load power, fed from mains and generator bus-bars.

Read more

ENKO MSU 4.0

Provides flexible start and control functions for Diesel Generators...

MSU4.0 control panel offers extensive start and control functions for Gen-Sets, where mains control is not required.

Read more

Now we are an industrial automation based distributor company who has wide experiance about process contol applications.

ÜÇEVLER MAH. 72 (220) SK AKNİL PLAZA NO: 6 KAT:3/41 16120 Nilüfer / BURSA-TURKEY
Phone: 0090 224 4414012
Email: [email protected]
MENU
  • About Us
  • Blog
  • Brands
  • Contact Us
2021 Csotrading.com. All Rights Reserved.
  • Blog