EZM-4435
Single Set Programmable Timer
EZM-XX35
Operation with Automatic and Manuel Reset
Programmable Time Bases (Second, Minute, Hour)
6 Digits process (PV) and 6 Digits Set (SV) Value Display
Single Contact Output for Timing control ( ON /OFF )
Operation with 1 Set Value
Reset, Pause and Start Inputs
Password protection for programming section
NPN/PNP Type Operation
EZM-4450
Multifunctional Programmable Timer and Counter with RS 232/485 Serial Communication Unit
EZM-XX50
Configurable Counter, Totalizer Counter, Batch Counter,
Timer, Chronometer, Frequencymeter and Tachometer
Operation with Automatic and Manuel Reset
Programmable Time Bases for Timer and Chronometer
Multiplication Coefficient and Decimal Point Position
6 Digits display
Reset, Pause and ChA-ChB Counting Inputs
Absolute or Offset Operation in Counter Function
Different Alarm Alternatives in Frequencymeter and
Cycle Measuring Functions
INC, DEC, INC/INC, INC/DEC, UP/DOWN,
x1 / x2 / x4 Counting with Phase Shifting Property in Counter
EZM-4930
Single Set Programmable Counter
EZM-XX30
Reset, Pause and ChA-ChB Counting Inputs
Multiplication Coefficient and Decimal Point Position
6 Digits process (PV) and 6 digits Set (SV) Value Display
Operation with 1 Set Value
NPN/PNP Type Operation
Operation with Automatic and Manuel Reset
INC, DEC, INC/INC, INC/DEC, UP/DOWN,
x1 / x2 / x4 Counting with Phase Shifting Property
EZM-4931
200 KHZ Programmable High Speed Counter
6 digits Process (PV) and 6 digits Set (SV) Value Display
Operation with 2 Set Value
Reset , Pause and ChA-ChB Counting Inputs
Operation with Automatic and Manual Reset
NPN/PNP input Types
x1 / x2 / x4 Phase Shifting Property
Multiplication Coefficient, Division Coefficient and Point
Position
Parametric , Two point (Low Scale - High Scale) and
Multiplication - Division Coefficient
RS-232 Serial Communication with Modbus RTU Protocol
Input Frequency Max. 200kHz
Max. Input Frequency Selection
EZM-4935
Single Set Programmable Timer
EZM-XX35
Operation with Automatic and Manuel Reset
Programmable Time Bases (Second, Minute, Hour)
6 Digits process (PV) and 6 Digits Set (SV) Value Display
Single Contact Output for Timing control ( ON /OFF )
Operation with 1 Set Value
Reset, Pause and Start Inputs
Password protection for programming section
NPN/PNP Type Operation
EZM-4950
Multifunctional Programmable Timer and Counter with RS 232/485 Serial Communication Unit
EZM-XX50
Configurable Counter, Totalizer Counter, Batch Counter,
Timer, Chronometer, Frequencymeter and Tachometer
Operation with Automatic and Manuel Reset
Programmable Time Bases for Timer and Chronometer
Multiplication Coefficient and Decimal Point Position
6 Digits display
Reset, Pause and ChA-ChB Counting Inputs
Absolute or Offset Operation in Counter Function
Different Alarm Alternatives in Frequencymeter and
Cycle Measuring Functions
INC, DEC, INC/INC, INC/DEC, UP/DOWN,
x1 / x2 / x4 Counting with Phase Shifting Property in Counter
EZM-7730
Single Set Programmable Counter
EZM-XX30
Reset, Pause and ChA-ChB Counting Inputs
Multiplication Coefficient and Decimal Point Position
6 Digits process (PV) and 6 digits Set (SV) Value Display
Operation with 1 Set Value
NPN/PNP Type Operation
Operation with Automatic and Manuel Reset
INC, DEC, INC/INC, INC/DEC, UP/DOWN,
x1 / x2 / x4 Counting with Phase Shifting Property
EZM-7735
Single Set Programmable Timer
EZM-XX35
Operation with Automatic and Manuel Reset
Programmable Time Bases (Second, Minute, Hour)
6 Digits process (PV) and 6 Digits Set (SV) Value Display
Single Contact Output for Timing control ( ON /OFF )
Operation with 1 Set Value
Reset, Pause and Start Inputs
Password protection for programming section
NPN/PNP Type Operation
EZM-7750
Multifunctional Programmable Timer and Counter with RS 232/485 Serial Communication Unit
EZM-XX50
Configurable Counter, Totalizer Counter, Batch Counter,
Timer, Chronometer, Frequencymeter and Tachometer
Operation with Automatic and Manuel Reset
Programmable Time Bases for Timer and Chronometer
Multiplication Coefficient and Decimal Point Position
6 Digits display
Reset, Pause and ChA-ChB Counting Inputs
Absolute or Offset Operation in Counter Function
Different Alarm Alternatives in Frequencymeter and
Cycle Measuring Functions
INC, DEC, INC/INC, INC/DEC, UP/DOWN,
x1 / x2 / x4 Counting with Phase Shifting Property in Counter
EZM-9930
Single Set Programmable Counter
EZM-XX30
Reset, Pause and ChA-ChB Counting Inputs
Multiplication Coefficient and Decimal Point Position
6 Digits process (PV) and 6 digits Set (SV) Value Display
Operation with 1 Set Value
NPN/PNP Type Operation
Operation with Automatic and Manuel Reset
INC, DEC, INC/INC, INC/DEC, UP/DOWN,
x1 / x2 / x4 Counting with Phase Shifting Property
EZM-9935
Single Set Programmable Timer
EZM-XX35
Operation with Automatic and Manuel Reset
Programmable Time Bases (Second, Minute, Hour)
6 Digits process (PV) and 6 Digits Set (SV) Value Display
Single Contact Output for Timing control ( ON /OFF )
Operation with 1 Set Value
Reset, Pause and Start Inputs
Password protection for programming section
NPN/PNP Type Operation
EZM-9950
Multifunctional Programmable Timer and Counter with RS 232/485 Serial Communication Unit
EZM-XX50
Configurable Counter, Totalizer Counter, Batch Counter,
Timer, Chronometer, Frequencymeter and Tachometer
Operation with Automatic and Manuel Reset
Programmable Time Bases for Timer and Chronometer
Multiplication Coefficient and Decimal Point Position
6 Digits display
Reset, Pause and ChA-ChB Counting Inputs
Absolute or Offset Operation in Counter Function
Different Alarm Alternatives in Frequencymeter and
Cycle Measuring Functions
INC, DEC, INC/INC, INC/DEC, UP/DOWN,
x1 / x2 / x4 Counting with Phase Shifting Property in Counter
Gencharger
Oven Controller (Dual)
Dual Zone Oven Controller
8 buttons to making different programs
2 isolated thermocupl input
J or K (It must be determined in order)
Auto-start feature with real time
ON / OFF temperature control for 2 areas
Limitation of set value
Adjustable temperature offset
Selection of operation with hysteresis
4 displays which has 3 digits and 2 diplays which has
4 digits (For clock)
Relay outputs to control 2 Heaters(no/nc),
4 Fans, Brulor, Steam,Lamp and Time-Out
1 door status input and 1 brulor failure input
For failure and set status internal buzzer
Password protection for programming mode
Oven Controller (Single)
Single Zone Oven Controller
8 buttons to making different programs
2 isolated thermocupl input
J or K (It must be determined in order)
Auto-start feature with real time
ON / OFF temperature control for 2 areas
Limitation of set value
Adjustable temperature offset
Selection of operation with hysteresis
4 displays which has 3 digits and 2 diplays which has
4 digits (For clock)
Relay outputs to control 2 Heaters(no/nc),
4 Fans, Brulor, Steam,Lamp and Time-Out
1 door status input and 1 brulor failure input
For failure and set status internal buzzer
Password protection for programming mode
PIDQUADRO
4 Channel PID Controller
Auto-Tuning and Self-Tuning
(Automatic calculations of PID parameters)
Data Logging to USB Flash Memory
Soft-Start (Ramp action during power on) specification
3 Different alarm types for each channel
(High, Low and Band Alarms)
128 x 64 Graphical LCD display
4 Thermocouple (J, K, L, R or S type) sensor inputs
Configurable P, PI, PD and PID control forms
Relay or (pnp “source”) transistor outputs
Operating with Real Time Clock (RTC)
ModBus RTU communication protocol
(Optional RS-232, RS-485 and Ethernet communication)
Trans-485
RS-485 Serial Communication Module
Easy plugging to all Trans Series controllers, RS-485 serial ModBus communication, Call-Back selection by Serial network, Maintenance management of multiple Gen-Sets from a central computer, Alarm observation and archive, Easy adjustable ID adress, Max. 247 device can be add on serial network, 500V galvanic insulation
Trans-AMF
Automatic Genset Controller with Transfer Switching
CanBus J1939 ECU communication
Selectable second language
Log last 50 events & alarm information with measured values
Statistics records
Mains and Generator phase sequence control
Selectable Resistive sender types; Pt-100, VDO, US, GM, Ford, Datcon, etc.
Automatic transfer switching control and engine control
SPN, FMI and OC values reading from engines via J1939
Trans-ATS
Automatic Transfer Switching Controllers
Authorised access, secure communication
Selectable second language
Log last 50 events & alarm information with measured values
Statistics records
Mains and Generator phase sequence control
Power factor measurement for 3 phases
Active, Reactive, Apparent power measurement
Trans-AUTO
Automatic Genset Controller
Canbus J1939 ECU communication
Selectable second language
Generator phase sequence control
Power factor measurement for 3 phases
Selectable Resistive sender types; Pt-100, VDO, US, GM, Ford, Datcon, etc..
SPN, FMI and OC values reading from engines via J1939
Active, Reactive, Apparent power measurement
Trans-CRANK
Trans-GPRS
Trans-Series GPRS Commumication Module
Easy plugging to all Trans Series controller,Gprs commumication, Alarm observatio and archive, DHCP supported, ModBus over TCP/IP comminication protocol, 2G, 2G5 EDGE supported, Suitable for telecommunication projects, GPRS antenna included With Gen-Agent,Multiple GenSet visualisation & control SCADA Software
Trans-I/O
Expansion Inputs/Outputs module
Easy plugging to all Trans series controllers, Configurable 8 inputs and 8 outputs, Each input and output configurable by user or select from list, Selectable hardware type of inputs by +Ve or -Ve, Selectable NO or NC input polarity, Selectable NO or NC output polarity, Adjustable input active delay, Can be used together with remote monitoring modules