Specifications
- Insulation Resistance
- 1000 MΩ minimum insulation resistance when measured at 500VDC at room temperature
- Certifications/Approvals
- Hazardous location, see full specs for complete list of certifications
- Lead Wires
- 24 AWG wire, FEP insulated. Color coded per IEC 60584 or ASTM E230.
- Insulation Resistance
- 1000 MΩ minimum insulation resistance when measured at 500VDC at room temperature
- Certifications/Approvals
- Hazardous location, see full specs for complete list of certifications
- Input
- Single sensor capability with universal sensor inputs (RTD, T/C, mV, ohms)
- Output Signal
- WirelessHART® protocol
- Housing
- Dual-compartment field mount
- Display/Interface
- Large LCD display with percent range graph
- Diagnostics
- Basic diagnostics including open/short sensor diagnostics
- Calibration Options
- Transmitter-sensor matching (Callendar-Van Dusen constants)
- Certifications/Approvals
- Hazardous location, marine type, see full specs for complete list of certifications
- Update Rate
- 1 sec. to 60 min., user selectable
- Power Module Life
- Up to 10-year life, field replaceable (order separately)
- Antenna Type
- External (standard and extended range)
Features
-
- Sensor types include J, K and T thermocouples for application flexibility
- Meets ASTM and IEC standards for thermocouple accuracy tolerance, providing reliable performance
- Covers a wide range of temperatures from -196 to 1200 °C (-321 to 2192 °F) for durability in varying process environments
- Withstands high vibration to offer resilience in tough process conditions
- Available in single or dual configurations with grounded or ungrounded junctions for process compatibility
- All sensor styles and lengths are available in ¼-in. diameter mineral-insulated (MI) cable to meet industry standards
- Adjustable or fixed compression fittings and spring-loaded or welded adapters meet specific mounting requirements
- Enclosure and connection head options allow for process adaptability
- Global hazardous location approvals to meet project requirements
-
- WirelessHART® technology is secure, cost-effective and delivers >99% data reliability
- Best-in-class wireless accuracy and stability for process automation
- Durable dual-compartment housing offers added field reliability
- Rosemount X-well Technology measures temperature without a process penetration for reduced design, installation and maintenance costs
- Transmitter-sensor matching produces better accuracy, matching exact sensor characteristics with the transmitter
- LCD display offers access to measurement and diagnostic information in the field, enhancing process visibility
- SmartPower™ module provides up to 10-year maintenance-free operation and field replacement without transmitter removal
- Easy installation enables quick instrumentation of measurement points without the cost of wiring