<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>G1-A Archives - CSO TRADING</title>
	<atom:link href="https://csotrading.com/product-tag/g1-a/feed/" rel="self" type="application/rss+xml" />
	<link>https://csotrading.com/product-tag/g1-a/</link>
	<description></description>
	<lastBuildDate>Thu, 02 Jul 2020 18:36:53 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.6.2</generator>

<image>
	<url>https://csotrading.com/wp-content/uploads/2023/11/cropped-fav-32x32.jpg</url>
	<title>G1-A Archives - CSO TRADING</title>
	<link>https://csotrading.com/product-tag/g1-a/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>270136 G1-A</title>
		<link>https://csotrading.com/product/270136-g1-a/</link>
					<comments>https://csotrading.com/product/270136-g1-a/#respond</comments>
		
		<dc:creator><![CDATA[CSO]]></dc:creator>
		<pubDate>Tue, 16 Jun 2020 20:06:31 +0000</pubDate>
				<guid isPermaLink="false">http://csotrading.com/?post_type=product&#038;p=3918</guid>

					<description><![CDATA[<p>Voltage monitoring relay</p>
<p>The post <a href="https://csotrading.com/product/270136-g1-a/">270136 G1-A</a> appeared first on <a href="https://csotrading.com">CSO TRADING</a>.</p>
]]></description>
										<content:encoded><![CDATA[<table class="table table-condensed">
<tbody>
<tr>
<td class="full" colspan="2"><strong>General</strong></td>
<td>Casing Width (mm)</td>
<td>17,5</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Connections</td>
<td>Screw Terminal</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Network</td>
<td>3Ø with Neutral</td>
</tr>
<tr>
<td><strong class="parent">Monitoring Functions</strong></td>
<td class="" colspan="1"><strong>Phase Failure</strong></td>
<td>Fixed Delay Time</td>
<td>500ms</td>
</tr>
<tr>
<td></td>
<td class="" colspan="1"><strong>Phase Sequence</strong></td>
<td>Fixed Delay Time</td>
<td>&#8212;</td>
</tr>
<tr>
<td></td>
<td class="" colspan="1"><strong>Adjustable/Fixed Unbalanced Protection</strong></td>
<td>Range/Limit</td>
<td>± 20%</td>
</tr>
<tr>
<td></td>
<td colspan="1"></td>
<td>Hysteresis</td>
<td>3% x Un ≈ 6,9VAC</td>
</tr>
<tr>
<td></td>
<td colspan="1"></td>
<td>Delay Time</td>
<td>2000msec</td>
</tr>
<tr>
<td></td>
<td class="" colspan="1"><strong>Adjustable Voltage Protection</strong></td>
<td>Upper Limit</td>
<td>&#8212;</td>
</tr>
<tr>
<td></td>
<td colspan="1"></td>
<td>Lower Limit</td>
<td>&#8212;</td>
</tr>
<tr>
<td></td>
<td colspan="1"></td>
<td>Hysteresis</td>
<td>&#8212;</td>
</tr>
<tr>
<td></td>
<td colspan="1"></td>
<td>Delay Time</td>
<td>&#8212;</td>
</tr>
<tr>
<td></td>
<td class="" colspan="1"><strong>Adjustable Current Protection</strong></td>
<td>Upper Limit</td>
<td>&#8212;</td>
</tr>
<tr>
<td></td>
<td colspan="1"></td>
<td>Lower Limit</td>
<td>&#8212;</td>
</tr>
<tr>
<td></td>
<td colspan="1"></td>
<td>Hysteresis</td>
<td>&#8212;</td>
</tr>
<tr>
<td></td>
<td colspan="1"></td>
<td>Delay Time</td>
<td>&#8212;</td>
</tr>
<tr>
<td></td>
<td class="" colspan="1"><strong>Adjustable Frequency Protection</strong></td>
<td>Upper Limit</td>
<td>&#8212;</td>
</tr>
<tr>
<td></td>
<td colspan="1"></td>
<td>Lower Limit</td>
<td>&#8212;</td>
</tr>
<tr>
<td></td>
<td colspan="1"></td>
<td>Hysteresis</td>
<td>&#8212;</td>
</tr>
<tr>
<td></td>
<td colspan="1"></td>
<td>Delay Time</td>
<td>&#8212;</td>
</tr>
<tr>
<td></td>
<td class="" colspan="1"><strong>Adjustable/Extremely High-Low Voltage Protection</strong></td>
<td>Upper Limit</td>
<td>&#8212;</td>
</tr>
<tr>
<td></td>
<td colspan="1"></td>
<td>Lower Limit</td>
<td>&#8212;</td>
</tr>
<tr>
<td></td>
<td colspan="1"></td>
<td>Hysteresis</td>
<td>&#8212;</td>
</tr>
<tr>
<td></td>
<td colspan="1"></td>
<td>Delay Time</td>
<td>&#8212;</td>
</tr>
<tr>
<td></td>
<td class="" colspan="1"><strong>PTC Protection</strong></td>
<td>Fixed Delay Time</td>
<td>&#8212;</td>
</tr>
<tr>
<td></td>
<td colspan="1"></td>
<td>Threshold</td>
<td>&#8212;</td>
</tr>
<tr>
<td class="full" colspan="2"><strong>General</strong></td>
<td>Response Time for Monitoring Any Function</td>
<td>Max. 250ms</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Type of Output</td>
<td>Relay</td>
</tr>
<tr>
<td class="full" colspan="2"><strong>Auxilary Contacts</strong></td>
<td>Type</td>
<td>1 C/O (SPDT)</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Max. Ratings &#8211; AC (for NO Side)</td>
<td>10A/250V; 1250 VA</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Max. Ratings &#8211; DC (for NO Side)</td>
<td>5A/30VDC; 150W</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Mechanical Lifetime</td>
<td>≥ 107 operations</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Electrical Lifetime Operations (for NO Side)</td>
<td>5×104 (5A@250VAC) 1×105 (5A@30VDC)</td>
</tr>
<tr>
<td class="full" colspan="2"><strong>Supply Voltage</strong></td>
<td>DC</td>
<td>&#8212;</td>
</tr>
<tr>
<td colspan="2"></td>
<td>AC</td>
<td>&lt;3VA</td>
</tr>
<tr>
<td class="full" colspan="2"><strong>General</strong></td>
<td>Supply Frequency</td>
<td>50-60Hz</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Control Input Voltage Range</td>
<td>&#8212;</td>
</tr>
<tr>
<td class="full" colspan="2"><strong>Ambient Conditions</strong></td>
<td>Operating Temperature</td>
<td>-20 to +60 °C</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Storing Temperature</td>
<td>-40 to +75 °C</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Relative Humidity (No Condensation)</td>
<td>Max. 95% (no condensation)</td>
</tr>
<tr>
<td class="full" colspan="2"><strong>General</strong></td>
<td>Operating Frequency</td>
<td>50-60Hz</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Protection Class</td>
<td>IP20</td>
</tr>
<tr>
<td class="full" colspan="2"><strong>Power Consumption</strong></td>
<td>DC</td>
<td>&#8212;</td>
</tr>
<tr>
<td colspan="2"></td>
<td>AC</td>
<td>&lt;3VA</td>
</tr>
<tr>
<td class="full" colspan="2"><strong>General</strong></td>
<td>Mounting Type</td>
<td></td>
</tr>
<tr>
<td colspan="2"></td>
<td>EMC-EMI</td>
<td>OK</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Packing Unit</td>
<td>1</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Weight (g)</td>
<td>66</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Packing Unit</td>
<td>1</td>
</tr>
</tbody>
</table>
<p>Klemsan protection relays protect system devices against unbalanced voltage and prevent errors caused by motor winding temperatures.</p>
<p>The post <a href="https://csotrading.com/product/270136-g1-a/">270136 G1-A</a> appeared first on <a href="https://csotrading.com">CSO TRADING</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://csotrading.com/product/270136-g1-a/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
