<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>606210 Archives - CSO TRADING</title>
	<atom:link href="https://csotrading.com/product-tag/606210/feed/" rel="self" type="application/rss+xml" />
	<link>https://csotrading.com/product-tag/606210/</link>
	<description></description>
	<lastBuildDate>Thu, 02 Jul 2020 19:33:55 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.6.2</generator>

<image>
	<url>https://csotrading.com/wp-content/uploads/2023/11/cropped-fav-32x32.jpg</url>
	<title>606210 Archives - CSO TRADING</title>
	<link>https://csotrading.com/product-tag/606210/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>606210 ECRAS 100</title>
		<link>https://csotrading.com/product/606210-ecras-100/</link>
					<comments>https://csotrading.com/product/606210-ecras-100/#respond</comments>
		
		<dc:creator><![CDATA[CSO]]></dc:creator>
		<pubDate>Tue, 16 Jun 2020 20:15:51 +0000</pubDate>
				<guid isPermaLink="false">http://csotrading.com/?post_type=product&#038;p=3925</guid>

					<description><![CDATA[<p>3Ø Multimeter</p>
<p>The post <a href="https://csotrading.com/product/606210-ecras-100/">606210 ECRAS 100</a> appeared first on <a href="https://csotrading.com">CSO TRADING</a>.</p>
]]></description>
										<content:encoded><![CDATA[<table class="table table-condensed">
<tbody>
<tr>
<td class="full" colspan="2"><strong>General</strong></td>
<td>Seven Segment Display</td>
<td>✔</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Password Protection</td>
<td>✔</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Current Transformer Ratio</td>
<td>1 &#8211; 5000</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Voltage Transformer Ratio</td>
<td>1 &#8211; 5000</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Demand Period</td>
<td>1-60 min. adjustable</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Connection Type</td>
<td>3F4T, 3F3T</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Measurements in Quadrants</td>
<td>4</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Number of Measurements in a Period</td>
<td>256</td>
</tr>
<tr>
<td colspan="2"></td>
<td>LCD/Display Refresh Period</td>
<td>1 sec.</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Networks</td>
<td>TT, TN, IT</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Min./Max./Demand Values</td>
<td>✔</td>
</tr>
<tr>
<td class="full" colspan="2"><strong>Energy Measurement</strong></td>
<td>Number of Tariffs</td>
<td>1</td>
</tr>
<tr>
<td colspan="2"></td>
<td>1Ø Phase Energy Meters</td>
<td>✔</td>
</tr>
<tr>
<td colspan="2"></td>
<td>3Ø Phase Energy Meters</td>
<td>✔</td>
</tr>
<tr>
<td class="full" colspan="2"><strong>Current Measurement Input</strong></td>
<td>Measurement Range</td>
<td>10mA &#8211; 6A AC</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Overvoltage Category</td>
<td>300 V Cat II</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Measurement Surge Voltage</td>
<td>2 kV</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Power Consumption</td>
<td>&lt;0.2 VA</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Intermittent Overload</td>
<td>100 A for 1 sec.</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Sampling Frequency between 45-65 Hz</td>
<td>12.8 kHz</td>
</tr>
<tr>
<td class="full" colspan="2"><strong>Voltage Measurement Input</strong></td>
<td>Overvoltage Category</td>
<td>300 V Cat III</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Measured Range L-N</td>
<td>1-300 Vrms</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Measured Range L-L</td>
<td>2-500 Vrms</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Measured Frequency Range</td>
<td>45-65 Hz</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Power Consumption</td>
<td>&lt;0.1 VA</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Sampling Frequency between 45-65 Hz</td>
<td>12.8 kHz</td>
</tr>
<tr>
<td class="full" colspan="2"><strong>Power Quality Measurements</strong></td>
<td>Harmonics for Current and Voltage Phases</td>
<td>Up to 31st</td>
</tr>
<tr>
<td colspan="2"></td>
<td>THD &#8211; Voltage in %</td>
<td>✔</td>
</tr>
<tr>
<td colspan="2"></td>
<td>THD &#8211; Current in %</td>
<td>✔</td>
</tr>
<tr>
<td class="full" colspan="2"><strong>Other Measurements</strong></td>
<td>Run Hour (Operating Time for Load in Hours)</td>
<td>✔</td>
</tr>
<tr>
<td colspan="2"></td>
<td>On Hour (Operating Time for Meter in Hours)</td>
<td>✔</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Int Counter (Number of Power Interruptions)</td>
<td>✔</td>
</tr>
<tr>
<td><strong class="parent">Measurement Accuracy</strong></td>
<td class="" colspan="1"><strong>According to IEC 61557-12</strong></td>
<td>Total Active Power</td>
<td>Class 0.5</td>
</tr>
<tr>
<td></td>
<td colspan="1"></td>
<td>Total Reactive Power</td>
<td>Class 1</td>
</tr>
<tr>
<td></td>
<td colspan="1"></td>
<td>Total Apparent Power</td>
<td>Class 0.5</td>
</tr>
<tr>
<td></td>
<td colspan="1"></td>
<td>Total Active Energy</td>
<td>Class 0.5</td>
</tr>
<tr>
<td></td>
<td colspan="1"></td>
<td>Total Reactive Energy</td>
<td>Class 2</td>
</tr>
<tr>
<td></td>
<td colspan="1"></td>
<td>Frequency</td>
<td>Class 0.1</td>
</tr>
<tr>
<td></td>
<td colspan="1"></td>
<td>Current</td>
<td>Class 0.5</td>
</tr>
<tr>
<td></td>
<td colspan="1"></td>
<td>Neutral Current</td>
<td>Class 0.5</td>
</tr>
<tr>
<td></td>
<td colspan="1"></td>
<td>Voltage</td>
<td>Class 0.2</td>
</tr>
<tr>
<td></td>
<td colspan="1"></td>
<td>Power Factor</td>
<td>Class 0.5</td>
</tr>
<tr>
<td></td>
<td colspan="1"></td>
<td>THDV, THDI</td>
<td>Class 1</td>
</tr>
<tr>
<td></td>
<td class="" colspan="1"><strong>According to IEC 62053-22</strong></td>
<td>Total Active Energy</td>
<td>Class 0.5S</td>
</tr>
<tr>
<td></td>
<td class="" colspan="1"><strong>According to IEC 62053-23</strong></td>
<td>Total Reactive Energy</td>
<td>Class 2</td>
</tr>
<tr>
<td><strong class="parent">Inputs and Outputs</strong></td>
<td class="" colspan="1"><strong>Alarm Relay Outputs</strong></td>
<td>Type</td>
<td></td>
</tr>
<tr>
<td></td>
<td colspan="1"></td>
<td>Max. Switching Current</td>
<td>10 A</td>
</tr>
<tr>
<td><strong class="parent">Supply</strong></td>
<td class="" colspan="1"><strong>Voltage</strong></td>
<td>AC</td>
<td>85-300V</td>
</tr>
<tr>
<td></td>
<td colspan="1"></td>
<td>DC</td>
<td>85-300V</td>
</tr>
<tr>
<td></td>
<td class="" colspan="1"><strong>Consumption</strong></td>
<td>AC</td>
<td>&lt;6VA</td>
</tr>
<tr>
<td></td>
<td colspan="1"></td>
<td>DC</td>
<td>&lt;3W</td>
</tr>
<tr>
<td class="full" colspan="2"><strong>Supply</strong></td>
<td>Frequency</td>
<td>45-65Hz</td>
</tr>
<tr>
<td><strong class="parent">Data Logging with timestamp</strong></td>
<td class="" colspan="1"><strong>Min./Max./Avg. Values</strong></td>
<td>Hourly Records</td>
<td></td>
</tr>
<tr>
<td></td>
<td colspan="1"></td>
<td>Daily Records</td>
<td></td>
</tr>
<tr>
<td></td>
<td colspan="1"></td>
<td>Monthly Records</td>
<td></td>
</tr>
<tr>
<td class="full" colspan="2"><strong>Data Logging with timestamp</strong></td>
<td>Demand</td>
<td></td>
</tr>
<tr>
<td class="full" colspan="2"><strong>Mechanical Properties</strong></td>
<td>Weight (g)</td>
<td>272 g</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Protection Class</td>
<td>Front IP40 / Rear IP20</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Mounting Type</td>
<td>Panel Mount</td>
</tr>
<tr>
<td><strong class="parent">Cable Cross Sections</strong></td>
<td class="" colspan="1"><strong>Supply, Voltage, Current, Relay Outputs</strong></td>
<td>Stranded:</td>
<td>2.5mm² &#8211; 14AWG</td>
</tr>
<tr>
<td></td>
<td colspan="1"></td>
<td>Solid:</td>
<td>4mm² &#8211; 12AWG, 2&#215;1.5mm² &#8211; 2x16AWG</td>
</tr>
<tr>
<td class="full" colspan="2"><strong>Ambient Conditions</strong></td>
<td>Operating Temperature</td>
<td>-20°C +70°C</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Storing Temperature</td>
<td>-30°C +80°C</td>
</tr>
<tr>
<td colspan="2"></td>
<td>Relative Humidity (No Condensation)</td>
<td>Max. 95%</td>
</tr>
<tr>
<td class="full" colspan="2"><strong>EMC-EMI</strong></td>
<td>300 VAC CAT II according to IEC 61010-1</td>
<td>✔</td>
</tr>
<tr>
<td colspan="2"></td>
<td>EN 55011/A1:2010, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN61000-4-11</td>
<td>✔</td>
</tr>
<tr>
<td class="full" colspan="2"><strong>Schematics</strong></td>
<td>Network Connections</td>
<td></td>
</tr>
<tr>
<td colspan="2"></td>
<td>Digital I/O and Alarm Output Connections</td>
<td></td>
</tr>
<tr>
<td colspan="2"></td>
<td>3 wires with 3CTs</td>
<td></td>
</tr>
<tr>
<td colspan="2"></td>
<td>4 wires with 3CTs</td>
<td></td>
</tr>
<tr>
<td colspan="2"></td>
<td>3 wires with 2CTsNOTE: CTs can be connected any phase. They are connected to phase 1 and phase 3 in this figure.</td>
<td></td>
</tr>
<tr>
<td colspan="2"></td>
<td>Single Phase with 1CTNORE: CT and VT can be connected any phase. They are connected to phase 1 in this figure.</td>
<td></td>
</tr>
<tr>
<td colspan="2"></td>
<td>Digital Output Connection</td>
<td></td>
</tr>
<tr>
<td colspan="2"></td>
<td>Digital Input Connection</td>
<td></td>
</tr>
<tr>
<td colspan="2"></td>
<td>Alarm Output Connection</td>
<td></td>
</tr>
<tr>
<td colspan="2"></td>
<td>Analog Output Connection</td>
<td></td>
</tr>
<tr>
<td class="full" colspan="2"><strong>General</strong></td>
<td></td>
<td></td>
</tr>
</tbody>
</table>
<p>The post <a href="https://csotrading.com/product/606210-ecras-100/">606210 ECRAS 100</a> appeared first on <a href="https://csotrading.com">CSO TRADING</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://csotrading.com/product/606210-ecras-100/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>